Candle filter is a filter with advanced filter cloth and unique control system. The filter cloth can realize automatic repeated cleaning, repeated use, long service life, etc. It can be used for precision filtration. It is suitable for: high content and fine particles. , corrosive, toxic and odorous and other harsh environments, automatic filtration.
Main performance:
-
lCompletely customize the whole set of filtration system according to customer requirements
-
lHigh-efficiency filtration, can achieve the smallest 0.2 micron filtration, can handle high solid content, strong corrosiveness, flammable and explosive and other difficult liquid filtration.
-
l Can do residual liquid filtration.
-
lCan be used for filter cake washing.
-
lCan be used for filter cake drying and automatic slag discharge.
-
l Can be concentrated and filtered.
-
lAutomatic cleaning of filter media.
-
lSimple operation, automatic closed operation.
Scope of application
Petrochemical: amine liquid, catalyst recovery, sulfuric acid, polyol, titanium dioxide, PTA particles, polyglycol, potassium carbonate, epoxy resin;
Biopharmaceuticals: fermentation extract, antibiotics, antibiotics, streptomycin, citric acid;
Food and beverage: apple juice, grape juice, raw syrup, fructose syrup, glucose syrup, sucrose, beer, olive oil, palm oil, soybean oil, corn oil, gelatin;
Wastewater treatment: electronic wastewater treatment, printing and dyeing wastewater treatment, chemical wastewater treatment, etc.
Product advantages
1) Completely airtight filtration, no leakage, no environmental pollution
2) The structure of the filter element adopts a duplex structure, and the flow rate is large
3) Pulse gas is used for back blowing and slag discharge, and the filter cake is easy to fall off, suitable for viscous materials
4) The operation process can be fully automated
Product parameters
model |
FC-J-5-40-50 |
FC-J-7-40 |
FC-J-11-50 |
FC-J-17-50 |
FC-J-23-100 |
FC-J-32-100 |
FC-J-56-100 |
FC-J-82-150 |
FC-J-108-150 |
FC-J-142-200 |
Filtration area(m2) |
5 |
7 |
11 |
17 |
23 |
32 |
56 |
82 |
108 |
142 |
Candle length(mm) |
1250 |
1650 |
1650 |
2500 |
2500 |
2500 |
2500 |
2500 |
2500 |
2500 |
Number of candles |
16 |
16 |
26 |
26 |
36 |
50 |
86 |
126 |
166 |
218 |
Equipment reorder(t) |
0.85 |
0.9 |
1.1 |
1.3 |
1.3 |
1.9 |
3.2 |
4.2 |
6.2 |
8.4 |
Equipment capacity (m3) |
1.3 |
1.5 |
2.1 |
2.8 |
3.7 |
4.8 |
8.5 |
12.2 |
16.6 |
22.0 |
Wave liquid outlet(DN) |
50*4 |
50*4 |
50*6 |
50*6 |
50*6 |
50*8 |
50*10 |
50*12 |
50*14 |
50*16 |
Raw liquid inlet(DN) |
40 |
40 |
50 |
50 |
100 |
100 |
100 |
150 |
150 |
200 |
Number of candles |
300 |
300 |
300 |
300 |
400 |
400 |
400 |
500 |
500 |
500 |
A(mm) |
150 |
150 |
165 |
165 |
250 |
250 |
250 |
280 |
280 |
300 |
B(mm) |
200 |
200 |
250 |
250 |
250 |
250 |
250 |
300 |
300 |
300 |
D(mm) |
400 |
400 |
450 |
450 |
480 |
500 |
640 |
720 |
790 |
880 |